Gamma-Metrics SL-GN Cement Slurry Analyzer
The Gamma-Metrics SL GNTM Analyzer provides a full elemental minute-by-minute analysis of cement slurry for quality control. Ensuring consistent and homogenized quality of raw material, slurry quality is the key to increased productivity and reduced manufacturing costs for the cement industry.
The Gamma-Metrics SL GNTM Analyzer provides full elemental minute-by-minute analysis of cement slurry for quality control. Ensuring consistent and homogenized quality of raw material slurry is the key to increase productivity and reduce manufacturing costs in a wet process plant. When the analyzer is installed for a tank blending application, the data generated by the Gamma-Metrics SL GN analyzer is used by the operator to conserve high grade materials while ensuring the consistent satisfaction of all quality control targets, such  as LSF. When installed for Raw Mix application the Gamma-Metrics SL GN Analyzer analysis coupled with the plant control network can provide high frequency quality control and optimization solution. This closed loop control will help reduce the raw mix quality fluctuations and provide a steady quality of kiln feed. The use of the analyzer in these applications will reduce kiln feed variability and lead to reduced consumption of fuel and electricity, while ensuring consistent on-spec product.

 

Specifications for: :Composition Monitor Module (CMM)
Dimensions :1.85 m L x 1.60 m W x 2.08 m H (73" L x 63" W x 83" H
Weight :3,200 kg (7,000 lb.)
Operating Temperature :-30 to 60°C (-22 to 140°F)
Humidity :0 to 100% (including rain)
Vibration :<0.5 G from 0 to 500 Hz
Shock :5 G, 10 msec max.
Atmosphere :Non-corrosive
Specifications for: :Information Processing Module (IPM-DSM)
Dimensions :0.31 m L x 0.76 m W x 1.07 m H (12" L x 30" W x 42" H)
Weight :90 kg (200 lb.)
Operating Temperature :-20 to 50°C (-4 to 122°F)
Humidity :0 to 100% (non-condensing)
Vibration :<0.1 G from 0 to 500 Hz
Atmosphere :Non-corrosive
Specifications for :Smart Materials Controller (SMC-NT)
Operating Temperature :10 to 35°C (50 to 95°F)
Non-Operating Temp. :0 to 40°C (50 to 95°F)
Humidity :20 to 80% (non-condensing)
Vibration :<0.1 G from 0 to 500 Hz
Atmosphere :Non-corrosive, dust-free